Important Notice & Disclaimer
Nature of Document: This presentation has been prepared and issued by ReNerve Ltd (Company) to provide general information about the Company. The information in
this document is in summary form and should not be relied upon as a complete and accurate representation of any matters that a reader should consider in evaluating
the Company. While management has taken every effort to ensure the accuracy of the material in this presentation, the Company have not verified the accuracy or
completeness of the material contained in this presentation.
Not an offer: this presentation should not be distributed, transmitted, or viewed by any person in any jurisdiction where the distribution, transmission or viewing of this
document would be unlawful under the securities or other laws of that or any other jurisdiction.
Not financial product advice: You should not act and should refrain from acting in reliance on this presentation. Nothing contained in this presentation constitutes
investment, legal, tax or other advice. This presentation does not take into account the individual investment objectives, financial situation and particular needs of potential
investors. Before making a decision to invest in the Company at any time, you should conduct, with the assistance of your broker or other financial or professional adviser,
your own investigation in light of your particular investment needs, objectives and financial circumstances and perform your own analysis of the Company before making
any investment decision.
Forward looking statements: This presentation contains forward-looking information about the Company and its operations. In certain cases, forward-looking information
may be identified by such terms as "anticipates", "believes", “should”, "could", "estimates", “target”, “likely”, “plan”, "expects", "may", “intend”, "shall", "will", or "would". These
statements are based on information currently available to the Company and the Company provides no assurance that actual results will meet management's
expectations. Forward-looking statements are subject to risk factors associated with the Company’s business, many of which are beyond the control of the Company. It is
believed that the expectations reflected in these statements are reasonable but they may be affected by a variety of variables and changes in underlying assumptions
which could cause actual results or trends to differ materially from those expressed or implied in such statements. There can be no assurance that actual outcomes will
not differ materially from these statements.
Disclaimer: No representation or warranty, express or implied, is made by the Company that the material contained in this presentation will be achieved or proved correct.
Except for statutory liability which cannot be excluded, the Company, its directors, officers, and employees expressly disclaim any responsibility for the accuracy, fairness,
sufficiency or completeness of the material contained in this presentation and excludes all liability whatsoever (including in negligence) for any loss or damage which may
be suffered by any person as a consequence of any information in this presentation or any effort or omission therefrom. The Company will not update or keep current the
information contained in this presentation or to correct any inaccuracy or omission which may become apparent, or to furnish any person with any further information. Any
opinions expressed in the presentation are subject to change without notice.
ReNerve Ltd ABN 23 614 848 216
2
Executive Summary
Development of Novel Nerve Repair &
Regeneration Products
ReNerve is focused on developing a portfolio of products for the nerve
repair and regeneration markets, with clearly defined commercial demand.
Significant Product Portfolio
ReNerve currently has one product in market with a clear commercial
pathway for FDA clearance of 3+ products over the next 4 years.
Strong Sales & Distribution Presence
ReNerve has established logistics, warehouse and invoicing infrastructure
with a strong focus on building a sales distribution network for all products.
3
Investment Highlights
IN MARKET PRODUCT
IMMEDIATE MARKET NEED
GROWING MARKET
Nerve Cuff transitioned from R&D to
Product offering promotes nerve injury
Nerve repair biomaterials market is
commercial sales post FDA market
recovery and regrowth leading to better
forecasted to grow by >17% pa, estimated
clearance, achieving strong initial product
patient recovery and outcomes.
to be worth >US$6.19Bn by 2031.
DIVERSE PRODUCT PORTFOLIO
GROWING DISTRIBUTION
BOARD & MANAGEMENT
One product already on the market
Continuing to build sales representation
Highly accomplished executive team with
(NervAlign® Nerve Cuff), with an additional
with a targeted-direct sales approach.
a proven track record in the development
margins.
three under development (NervAlign®
& commercialisation of medical
Nerve Conduit, Nerve Guide Matrix and
opportunities.
Bionic Nerve).
4
Company History
2017
ReNerve Ltd
established with the
aim to improve short
and long-term
outcomes for patients
undergoing surgery
relating to peripheral
nerve damage.
2018
2019
Positive animal studies
for the Nerve Cuff and
Nerve Guide Matrix.
2020
2021
2022
Received marketing
approval for NervAlign®
Nerve Cuff in New Zealand.
2023
2024
Entered into a
commercial
partnership with
Collagen solutions for
the Nerve Guide Matrix.
Received FDA
guidance on pathway
for market clearance
for the Neve Guide
Matrix.
ReNerve entered into a
development and
manufacturing
agreement with
Biomedical Europe B.V.
Established US
warehousing and
logistics ahead of US
market approval.
Received FDA clearance for
the NervAlign® Nerve Cuff,
achieving first sales.
Entered into a commercial
partnership with Yuan Yu
to gain approval and
market the product in
Taiwan.
Initial Public Offering
on the ASX.
5
Global Nerve Repair Biomaterial Market*
Global Market by
Segment*
$8.0Bn
16%
$6.0Bn
32%
USD $Bn
Global Nerve
Repair
Biomaterial
Market*
$4.0Bn
52%
$2.0Bn
Nerve Wrap
Nerve Conduit
2024
2025
North America
2026
Europe
2027
Asia Pacific
2028
Latin America
2029
2030
Nerve Grafts
2031
Middle East & Africa
USD$1.69Bn*
~900k
Nerve Compression
The Global Nerve Repair Biomaterials Market was valued at USD$1.69Bn
Nerve surgeries occur in the United States (US) per annum, with no
Approximately 1-in-4 nerve repair cases receive surgery repair, with
in 2023 and is projected to grow at a compound annual growth rate
more than 24% of nerve surgeries restoring to ‘as good as it was’.
30% failure/revision rates.
(CAGR) of 17.8% from 2024 to 2031 to USD$6.19Bn.*
* Please refer to the Global Nerve Repair Biomaterials Report (2020 – 2031) and/or the ReNerve Prospectus for full details on Key Data for the Global Market
6
ReNerve’s Opportunity
Nerve Cuff
Application
Nerve Guide Matrix
Bionic Nerve
•
Used on damaged or transected
nerves with no gaps or gap closure
•
Improved Nerve Cuff developed from
scCO2 tissue, offering better product
profile
•
An ‘off-the-shelf’, ready to use nerve
graft replacement with internal
guidance infrastructure
•
An ‘off-the-shelf’, continuous nerve
replacement, in a ready to use nerve
structure
•
End to end suturing covered with a
wrap/cuff
•
Protecting injured nerve repairs
•
•
•
Protective cuff for grafts
Replaces damaged nerve section
instead of using donor or harvested
tissue
The Bionic Nerve is a nerve guide
matrix with ionic polymers designed
to replace injured and damaged
nerves for lengths from 1cm to 20cm
•
Trauma
•
Trauma
•
Trauma
•
Trauma
•
Breast reconstruction
•
Breast reconstruction
•
Breast reconstruction
•
Craniotomy
•
Orthopedics
•
Orthopedics
•
Orthopedics
•
Spinal cord injury
•
Oral & maxillofacial surgery
•
Foot and ankle
•
Hand & wrist
•
Spinal cord surgery
•
Bio-absorbed removing need for
additional surgery
•
Can be cut to ideal length
•
Off-the-shelf, reducing logistics issues
•
•
Simple to use and cost effective
Enable production of nerves of
bespoke dimension
Product
Procedure Use
Nerve Conduit
Benefit
•
Pliable and conforms
FDA Status
FDA Cleared
•
Improved product profile to Nerve Cuff
•
Stronger patient reimbursement
Targeting Q4 CY25 filing
Targeting Q2 CY27 filing
Targeting Q3 CY28 filing
$3219m
TAM (USD)
$975m
$314m
2024
2030
$1991m
$1015m
2024
$635m
2030
2024
>$400m
2030
2023
7
PNI Classification
Traditional Treatment Methods
Suture
•
Transection
•
Can result in tension at repair site
leading to ischemia
Concentrates sutures at
coaptation site
Vein Wrapping
Compression
•
Requires additional surgical time
•
Specific surgical skill
•
Creates secondary surgical site
Transection Neurectomy
Synthetic Conduits
•
Loss of function at harvest site
•
Limited direction for regrowth
•
Complication risk including
chronic pain
•
Increased failure rate >5mm gaps
•
Repair relies on fibrin clot
formation
•
Limited graft length
Hypothenar Fat Pad
Collagen Wraps
•
Only wraps part of the nerve
circumference
•
Increases surgical procedure time •
•
Creates an inhibitor to
surrounding tissue
Burying in Muscle / Bone
Can lead to additional neuroma
and secondary surgery
•
•
Traction injury
•
Pain and localised pressure
•
High risk of recurrence
•
Large surgical dissection
•
Stump Neuroma
Autograft
ReNerve Solution
Can lead to additional neuroma
and secondary surgery
•
Semi-rigid material limits surgical
use
Degrades over time
Injections
•
Success rate estimated ~40%
•
Temporary solution that reduces
over time
•
Pharmacological side effects
Existing PNI Treatment Methods
8
Issues with Existing Nerve
Repair Methods
US Nerve Procedural Breakdown
2%
ReNerve’s Opportunity
6%
14%
Method
Limitations
•
Suture
Autograft
Nerve Transfer
Can result in tension to the repair
leading to ischemia.
•
Concentrates sutures at the coaptation
site.
•
Loss of function and sensation at donor
site resulting in morbidity for the patient.
•
High complication rates including wound
healing and chronic pain.
•
Mismatch in size and structure due to
limited availability of graft length and
diameter, affecting quality of nerve
regeneration.
•
Variable functional recovery.
•
Limited to small gaps due to size and
shape constraints, reducing efficacy and
use.
Synthetic Conduits
ReNerve Solution
•
Variable functional recovery.
•
Sacrifice of function in the donor nerve’s
original target area.
•
Mismatch in size and structure.
•
Delayed reinnervation.
•
Variable functional recovery.
78%
Trauma
Carpal & Cubital Tunnel Revisions
Oral Mxillofacial
Breast Neurtization Procedures
Surgical Transections Resulting in Nerve Damage
60%
Limb Amputation
20%
20%
20%
20%
20%
Mastectomy
Thoractomy
Post Hernia Repair
Low
High
9
Distribution Network
Defined sales strategy targeting the US as five
regions, with aggressive focus to continue building
regional sales representation.
Using third party distribution partnerships and
1099s.
Established sales presence in target states with a
focus on key hospital systems in each region.
Warehousing, invoicing and logistics all in place
with additional infrastructure to support nerve
conduit and guide matrix sales.
10
Anticipated Company Milestones
(Next 12 – 24 Months)
Ongoing
Q1 2025
• Continue to Build Sales &
Distribution Across US
Mid-2025
Q4 2024 – Q4 2025
• Partnerships and Approvals for
the NervAlign® Nerve Cuff in New
Countries and Jurisdictions:
2H 2025
2026
Onwards
Q1 2026
• Complete Development for
NervAlign® Nerve Conduit
• Asia
• Commence Testing Conduit
for FDA Filing
• Central America
• Nerve Cuff Variant Launch
• First Clinical Graft Cases
• Progress Dura Mater Project to
Pre-Submission Testing
• South America
• Middle East
• Europe
• NervAlign® Nerve Cuff
Clinical Study Data and
Presentation
• Progress Nerve Graft Towards
GMP Manufacturing Run
• File New Nerve Conduit
Indication with FDA
• Testing of Bionic Nerve
Prototype
• Commence Final Product
Testing for Nerve Graft
FDA Submission
11
NervAlign® Nerve
Cuff
12
Key Features
Clinical Use
Product
Patient Results
• The NervAlign® Nerve Cuff is an FDA cleared product used on
damaged or transected nerves with no gaps or gap closure
achieved by flexion.
• 80% of cases to date have been focused on hand and wrist.
• The product is used as a barrier between the repaired nerve and
surrounding tissue.
Patient Benefit
• Bio-absorbed within 6-months.
• Produced using a non-toxic method.
• Clinical cases have:
✓ All reported positive outcomes; and
✓ Shown better than expected outcomes for patients
Clinical Use
• Received positive feedback from surgeons stating it handles well, is pliable
and conforms and has resulted in strong patient outcomes.
• Terminally sterilised with no residual chemicals.
• ReNerve has started to explore podiatry, breast and urology as areas
beyond hand and wrist.
• Covered under procedural reimbursement rather than individual
product reimbursement.
• Has been used with attachment methods including sutures, glue, micro
clips and ‘nothing’.
• Promotes vascular tissue formation on surrounding fascia tissue
post-implant.
Surgeon Benefit
• Requires no change to surgical technique or procedures.
• Available in various sizes and thickness with ability to be trimmed
to required shape.
• Is pliable and conforms.
13
Incorporating eCOO®Technology
eCOO® Technology
eCOO® Clean
Benefits Over Conventional
Tissue Treatments
Uses carbon dioxide under pressure to
create a gas and liquid state.
eCOO® Technology is ideal for cleaning
and sterilising tissue as it permeates
like a gas and cleans like a liquid.
• Retains structural & mechanical
properties.
• Maintains natural crosslinking of
extracellular matrix (ECM).
• Environmentally friendly.
• Promotes cell attachment.
• Process ensures effective viral &
pathogen inactivation.
• Low immunogenic risk.
Contains no:
• Deep microstructural penetration.
• Glutaraldehyde, Triton X-100,
sodium dodecyl sulphate (SDS),
acetone and enzymes; and
• Minimal residues & hazardous
materials.
• Ethylene oxide (EtO).
14
Clinical Use
Damaged nerve removed from the
right thumb
Removed gap filled with a conduit
NervAlign® Nerve Cuff used to
Completed repair held in place with
protect the cuff conduit implant
micro clips
15
Clinical Use - Carpal Tunnel
Carpal tunnel revision – exposed nerve
Implanted NervAlign® Nerve Cuff
used as a protective layer between the nerve and surrounding fascia
tissue. The cuff sutured in place using the ‘taco’ method.
16
NervAlign®
Conduit
17
Key Features
• ReNerve is focused on developing a conduit from scCO2 tissue
from the Nerve Cuff.
• ReNerve will be able to leverage existing data from the Nerve Cuff
FDA application to accelerate FDA clearance.
• Offers the followings benefits:
— Expands the ReNerve product range and portfolio;
— Better reimbursement for the conduit; and
— Same outcome and better product profile as the Nerve Cuff.
• ReNerve is targeting a Q4 CY25 FDA filing.
18
NervAlign® Nerve
Guide Matrix (Graft)
19
Key Features & Guide Matrix
Product
• The NervAlign® Neve Guide Matrix is an ‘off-the-shelf’, ready to use
nerve graft replacement with internal guidance infrastructure.
• ReNerve is developing three product options:
— Initial ‘wet’ prep nerve graft;
— Dry version that's hydrated within 10 minutes; and
— Longer lengths out to 7cms+.
Current Options
• Harvesting patients own nerves.
• Donor tissue graft.
• Conduits (for smaller repairs).
Benefit
• ReNerve Nerve Guide Matrix offers many benefits, including:
— Doesn’t create secondary surgical site;
— Stored at room temperature, removing storing issues;
— Doesn’t go through Wallerian degradation;
— Ease of use allows for immediate repairs;
— Longer lengths enables surgical revisions;
— More cost effective to existing options; and
— Positive outcomes post-surgery.
20
Autologous Implantation Study
NervAlign® Nerve Guide Matrix (Graft)
Nerve graft models have shown:
Animal study results showed:
• Restored ‘native’ state of nerves and function.
✓ Ready to implant and no special training required.
• Formation of functioning axons through full length of the nerve.
✓ Rapid recovery post surgery.
• Showed formation of fascicular like structures over the four-month
implantation period.
✓ Histology showed nerve regrowth through grafts equivalent to
autologous (native) tissue.
• Nerve function at the distal end of the limbs.
✓ Full nerve formation through entire length of nerve graft – including
new axon and fascicular formation and functional nerves.
The study also showed:
• Rapid recovery of the animals post-surgery.
• Walking with splint within hours.
• ~3 months to full recovery (‘normal walking’).
• Re-established motor and sensory function after implant surgery.
• No short- or long-term complications.
Key findings across the 3, 6 and 10-month measurements showed:
✓ 3 Months: Displayed typical post-surgery inflammation and gait of
animals restored.
✓ 6 Months: Inflammation in the graft and scar tissue around the
implants had reduced.
✓ 10 Months: Nerve conductance had been re-established to similar
levels, indicating functionality of the nerves.
1Source: Tullow Oil & Africa Oil Corp Presentations & Website
NervAlign® Nerve Guide Matrix Vs Autologous
Implantation Study
21
Regulatory Framework
Ethics Approval
FDA Meeting
Commercial
Partnership
FDA Clearance
✓
✓
✓
Received ethics approval for the
animal model study including
electrophysiology data.
Outlined positive path forward for
ReNerve, requiring no initial clinical
study in the US.
Executed partnership with Collagen
Solutions for commercial scale
production.
ReNerve have established a clear
path to FDA clearance and
product launch.
Allowed for use of larger size
implants.
Opens market for the ROW.
Phase 1 – Final product packing
studies.
Phase 2 – Scale Production of the
graft.
Phase 3 – Validation Batch Runs.
Phase 4 – Bench testing for FDA
submissions.
Current animal study is testing
electrophysiological development
of the nerve regrowth through the
graft with numerous implant
results expected over next 10
months.
22
NervAlign® Bionic
Nerve
23
NervAlign®
Bionic Nerve
ReNerve's NervAlign® Bionic
Nerve is intended to be an offthe-shelf, continuous nerve
• ReNerve are developing the Bionic Nerve to be in lengths from 1cm to 20cm+ long, in a ready to
use nerve structure, to replace damaged nerves.
• ReNerve are seeking to develop an effective solution for the most challenging nerve repair.
replacement.
• The Bionic Nerve will enable production of nerves of bespoke dimensions and incorporation of
neurostimulation.
Current practice is to use donor
• ReNerve have recently executed a collaboration partnership with 3DBioFibR for the development
of the Bionic Nerve.
or autologous nerves if possible,
however is limited by length.
Generally, nerves regrow at or
around 1mm per day in a stable
environment, however
outcomes are poor over 2cm-
5cm, becoming progressively
worse as regrowth distance
increases.
24
Dura Mater
Replacement
ReNerve are currently developing two products for the replacement
of Dura Mater.
1
2
Product One – Short term, remodeling dura replacement
•
For small craniotomies and back/spinal surgery.
•
Dura tissue-based on the nerve cuff eCOO® Technology.
•
Designed to be sutured in place and allow for
remodeling repair.
•
Very clean and avoids chemical meningitis seen with
other products.
• Aiming for first FDA submission within 18-months.
• ReNerve will seek to expand into novel multifunctional dura product.
Product Two – Long term dura replacement
•
Multi-functional product.
•
Sealed, anti-adhesion product for all craniotomies and
spinal surgery.
•
Antibacterial to prevent surgical site infections.
25
Board & Management
26
Board & Management
STEPHEN COOPER
CHAIRMAN
DR JULIAN CHICK
CEO & MANAGING DIRECTOR
DR MICHAEL PANACCIO
NON-EXECUTIVE DIRECTOR
DR DAVID RHODES
EXECUTIVE DIRECTOR & CSO
DR ALEX ADAMIDES
CHIEF MEDICAL OFFICER
Stephen was previously a
Managing Director at Grant
Samuel, a leading Australian
investment bank.
Dr Julian Chick is an experienced
healthcare executive with over 20
years’ experience in senior
management including in ASX
listed companies Avexa and
Admedus, and is currently NonExecutive Director at LTR Pharma
(ASX:LTP).
Dr Michael Panaccio is one of the
founders of Starfish Ventures, a
venture capital firm that invests in
early-stage technology
companies and plays an active
role in the management of its
portfolio.
Dr David Rhodes has more than 20
years’ experience in healthcare
and biotechnology industries,
where he has held numerous
senior management roles and
developed technologies through to
market approval.
Dr Alex Adamides studied
medicine at the University of
Nottingham, UK, and completed his
basic surgical training in Edinburgh
before undertaking his
neurosurgical training in Australia.
Michael has been a director of
numerous technology businesses
in Australia and the USA including
SIRTeX Medical Ltd, Engana Pty Ltd
(acquired by Optium Inc), Energy
Response (sold to EnerNoc Inc),
ImpediMed Ltd, and Protagonist
Therapeutics Inc.
David has been involved in
obtaining several FDA USA and
European marketing authorisation
approvals for medical devices.
Stephen has over twenty-five
years of experience in Investment
Banking and has been responsible
for numerous corporate advisory
assignments including public
company takeovers, mergers,
business sales and acquisitions,
schemes of arrangement, capital
raisings and business valuations.
Stephen has previously served as
Chairman of Avexa, an ASX-listed
biotechnology company.
Julian’s previous roles include
Chief Executive Officer, COO and
Head of Business Development, as
well as running early and latestage R&D projects and launching
medical devices into the global
markets.
Julian has been involved in
developing and obtaining FDA USA
clearance for four tissue based
medical devices. Julian, while COO
at Admedus Ltd was involved in
the R&D development, regulatory
clearance and launch of several
tissue products in North America,
Europe and Asia.
Julian has eight years’ investment
banker experience focused on
healthcare and biotechnology.
Julian has a PhD in Muscle
Physiology.
He currently serves on the boards
of MetaCDN Pty Ltd, Margin Clear
Pty Ltd, Marp Therapeutics Pty Ltd
and Cylite Pty Ltd.
Previous roles include senior
researcher at Amrad, Chief
Scientific Officer of the medical
devices company Admedus Ltd,
COO of AdAlta Ltd and senior
executive and Head of Drug
Discovery and Senior Vice
President Biology at Avexa Ltd.
David has successfully led multiple
technology development
programs attracting significant
levels of funding from many State
and Federal Government initiatives
and research institute programs.
Dr Adamides became a fellow of
the Royal Australasian College of
Surgeons in 2012 and has since
been a consultant neurosurgeon
at the Royal Melbourne Hospital.
Dr Adamides is an honorary
clinical senior lecturer at
Melbourne University and a
reviewer for the Journal of Clinical
Neuroscience.
Working with ReNerve, Dr
Adamides has developed preclinical models testing the safety
and efficacy of surgical implants
for the repair of peripheral nerves
and dura.
David has a PhD in Biochemistry.
27
Contact
E: info@ReNerve.com.au
+61 (03) 9482 3940
157 Heidelberg Rd,
Northcote VIC 3070
www.renerve.com.au
Investor Presentation | November 2024
28
Appendix
29
Key Risks
Insufficient funding
Rejection or delay in
receiving regulatory
approvals
ReNerve is in the medical devices business and such businesses require additional capital from time to time in order to progress development programs. There is no
guarantee that ReNerve will be able to raise the funds required in a timely manner or at a reasonable cost when required by it.
In February 2022, ReNerve received market clearance from the FDA for its primary product, the NervAlign® Nerve Cuff. FDA Market Clearance was granted in response to
ReNerve’s submissions and engagements with the FDA. The NervAlign® Nerve Cuff is designated as a Class II medical device.
All ReNerve’s other products will require regulatory approvals, in most cases as medical devices. Rejection, delay or subsequent loss of regulatory approvals could
impact the business. Jurisdictions outside of the US will likely require clinical data and ReNerve is engaging surgeons in Australia and in the US. to support the
generation of suitable data. In addition, once regulatory approval is obtained in the US, clinical data can be obtained and used to support additional regulatory filings.
The Directors assess rejection or delay risks for other approvals as low given the Company’s significant internal expertise in obtaining these types of clearances.
Non-acceptance of
ReNerve products by
surgeons
ReNerve’s marketing strategy relies on acceptance of its products by surgeons. ReNerve has an advisory Board of established surgeons in the U.S. who provide
guidance on product development and use the product in the U.S. and therefore the Directors are confident the products commencing with NervAlign® Nerve Cuff will
be accepted by surgeons.
Competition
ReNerve competes against many existing and potential competitors. ReNerve’s competitors may be able to increase market share through aggressive marketing
campaigns, product improvements, acquisitions or price discounting which may affect ReNerve’s market share and margins.
Limited history in sales
ReNerve has only two years of experience in the sales and marketing of nerve repair products in the U.S. market. There is no guarantee that it will be able to achieve its
sales goals, particularly given the uncertain nature and extent of competition from established market participants and new entrants with new products.
Product pipeline and
development of new
products
ReNerve’s ongoing commercial success is dependent on the continued advancement of existing products and the research and development of new products.
Developing new products is expensive and time consuming and products may fail to reach market or sell.
Loss of EMCM exclusivity
ReNerve currently has exclusivity under the EMCM Agreement (its Manufacturing and Supply Agreement). Exclusivity is dependent on achieving certain production
targets. Loss of exclusivity could expose the NervAlign Nerve Cuff to greater competition. See section 10.2 of the Prospectus for more information on the EMCM
Agreement. ReNerve considers it unlikely that it will not be able to meet the terms of exclusivity in the EMCM Agreement and maintains a strong, ongoing relationship
with EMCM.
Termination of EMCM
Agreement
Termination of the EMCM Agreement is unlikely but is possible if ReNerve breaches its obligations or if EMCM became insolvent or otherwise incapable of performing its
obligations. If it was terminated, ReNerve would be protected initially by the fact that ReNerve’s NervAlign® Nerve Cuff product has a 30-month shelf life, meaning that
ReNerve could service its market with existing product supplies until a new manufacturer could be established. ReNerve currently has a licence to the Leader IP (see
section 2.13). The licence is revocable only in the case ReNerve breaches the terms of the licence or its obligations under the EMCM Agreement. ReNerve believes that if
EMCM became insolvent or otherwise incapable of performing its obligations, ReNerve would not be prevented from continuing to manufacture and distribute the
NervAlign® Nerve Cuff product through an alternative manufacturer. However ReNerve would need to work with such alternative manufacturer to develop a method
and process for manufacturing the NervAlign® Nerve Cuff, which could be a substantial exercise.
30
Key Risks
Manufacturing and
production risks - EMCM
EMCM has the technical experience and processes to manufacture the NervAlign® Nerve Cuff. If EMCM were unable to continue operations for example due to loss of
accreditation or insolvency, or alternatively the agreement with EMCM was breached and terminated, ReNerve would then need to source a new manufacturer and
complete technology transfer would be required. The new manufacturer would need to obtain access to the IP including know-how of EMCM. Naturally, there is also risk
associated with increased production costs imposed by EMCM.
Manufacturing and
production risks –
manufacturing location /
premises
ReNerve’s products are manufactured in a single location by EMCM, and as such that location is exposed to risks of harm caused by natural or man-made disasters, or
operation or human error, which may result in manufacturing disruptions or an inability to manufacture and produce its products for some time. This has the potential
to limit, delay or prevent supply of ReNerve’s products and have an adverse impact on the availability of ReNerve’s products to customers, which would affect
contractual obligations, particularly with respect to failure to supply. ReNerve has entered into a partnership with Collagen Solutions for the manufacturing of its nerve
guide matrix. Collagen Solutions is also an alternative manufacturer of ReNerve’s other products.
Manufacturing and
production risks – raw
materials
Key raw materials used in the manufacture of the product include pigs sourced from the Netherlands. In turn, if there is to be any virus or other external force majeure
event that diminishes access to these resources, this could have an adverse effect on the manufacture of ReNerve’s product (by causing delay). EMCM and ReNerve
are assessing additional porcine raw material suppli